Files
report-temperatura/report_completo.tex
T

121 lines
4.2 KiB
TeX
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
\documentclass[11pt,a4paper]{article}
\usepackage[utf8]{inputenc}
\usepackage[T1]{fontenc}
\usepackage[margin=2.5cm]{geometry}
\usepackage{amsmath,amssymb}
\usepackage{booktabs}
\usepackage{graphicx}
\usepackage{float}
\usepackage[table]{xcolor}
\usepackage{hyperref}
\usepackage{fancyhdr}
\definecolor{darkblue}{HTML}{1a3a5c}
\pagestyle{fancy}\fancyhf{}
\rhead{\textcolor{darkblue}{\small Cevolani S.p.A.}}
\lhead{\textcolor{darkblue}{\small Analisi Termica Forno}}
\rfoot{\thepage}
\lfoot{\textcolor{gray}{\tiny Ver. 1.0 -- 14/05/2026}}
\title{\textbf{Report Analisi Termica Forno}\\[0.5em]\large Caratterizzazione termica degli induttori}
\author{Ufficio Tecnico – Cevolani S.p.A.}
\date{\today}
\begin{document}
\maketitle
\tableofcontents
\newpage
\section{Modello di fitting}
Ogni intervallo è interpolato con il modello di raffreddamento di Newton:
\begin{equation}
T(t) = T_\infty + A \cdot e^{-(t-t_0)/\tau}
\end{equation}
dove $T_\infty = 22{,}99\,^\circ\mathrm{C}$ è la temperatura ambiente media ponderata.
La regressione non lineare usa il metodo \textit{Trust Region Reflective} (TRF)
di \texttt{scipy.optimize.curve\_fit}.
\section{Report Induttore 1}
\subsection{Intervallo di campionamento}
\begin{tabular}{ll}\toprule
\textbf{Parametro} & \textbf{Valore} \\\midrule
Inizio & $110.81$ s \\
Fine & $111.56$ s \\
Numero di punti & 5 \\
\bottomrule\end{tabular}
\subsection{Equazione trovata}
\begin{equation}
T(t) = 22.99 + 87.3140 \cdot e^{-(t - 110.81) / 15.7231}
\end{equation}
\begin{tabular}{lll}\toprule
\textbf{Param.} & \textbf{Valore} & \textbf{Incertezza ($1\sigma$)} \\\midrule
$A$ & $87.3140\,^\circ\mathrm{C}$ & $\pm\,0.0260\,^\circ\mathrm{C}$ \\
$\tau$ & $15.7231\,\mathrm{s}$ & $\pm\,0.2021\,\mathrm{s}$ \\
$R^2$ & \multicolumn{2}{l}{0.999505} \\
\bottomrule\end{tabular}
\subsection{Grafico}
\begin{figure}[H]\centering
\includegraphics[width=0.9\textwidth]{C:\Users\davide.grilli\Desktop\vs\temperatura\induttore1\induttore1.png}
\caption{Fit esponenziale -- Report Induttore 1 [110.81 – 111.56 s]}
\end{figure}\newpage
\section{Report Induttore 2}
\subsection{Intervallo di campionamento}
\begin{tabular}{ll}\toprule
\textbf{Parametro} & \textbf{Valore} \\\midrule
Inizio & $112.02$ s \\
Fine & $113.95$ s \\
Numero di punti & 12 \\
\bottomrule\end{tabular}
\subsection{Equazione trovata}
\begin{equation}
T(t) = 22.99 + 158.3430 \cdot e^{-(t - 112.02) / 13.2844}
\end{equation}
\begin{tabular}{lll}\toprule
\textbf{Param.} & \textbf{Valore} & \textbf{Incertezza ($1\sigma$)} \\\midrule
$A$ & $158.3430\,^\circ\mathrm{C}$ & $\pm\,0.2088\,^\circ\mathrm{C}$ \\
$\tau$ & $13.2844\,\mathrm{s}$ & $\pm\,0.2183\,\mathrm{s}$ \\
$R^2$ & \multicolumn{2}{l}{0.997314} \\
\bottomrule\end{tabular}
\subsection{Grafico}
\begin{figure}[H]\centering
\includegraphics[width=0.9\textwidth]{C:\Users\davide.grilli\Desktop\vs\temperatura\induttore2\induttore2.png}
\caption{Fit esponenziale -- Report Induttore 2 [112.02 – 113.95 s]}
\end{figure}\newpage
\section{Report Induttore 3}
\subsection{Intervallo di campionamento}
\begin{tabular}{ll}\toprule
\textbf{Parametro} & \textbf{Valore} \\\midrule
Inizio & $115.0$ s \\
Fine & $133.7$ s \\
Numero di punti & 125 \\
\bottomrule\end{tabular}
\subsection{Equazione trovata}
\begin{equation}
T(t) = 22.99 + 185.1847 \cdot e^{-(t - 115.0) / 16.2654}
\end{equation}
\begin{tabular}{lll}\toprule
\textbf{Param.} & \textbf{Valore} & \textbf{Incertezza ($1\sigma$)} \\\midrule
$A$ & $185.1847\,^\circ\mathrm{C}$ & $\pm\,0.2706\,^\circ\mathrm{C}$ \\
$\tau$ & $16.2654\,\mathrm{s}$ & $\pm\,0.0464\,\mathrm{s}$ \\
$R^2$ & \multicolumn{2}{l}{0.993827} \\
\bottomrule\end{tabular}
\subsection{Grafico}
\begin{figure}[H]\centering
\includegraphics[width=0.9\textwidth]{C:\Users\davide.grilli\Desktop\vs\temperatura\induttore3\induttore3.png}
\caption{Fit esponenziale -- Report Induttore 3 [115.0 – 133.7 s]}
\end{figure}\newpage
\section{Riepilogo}
\begin{tabular}{lllll}\toprule
\textbf{Induttore} & \textbf{Intervallo [s]} & \textbf{A [°C]} & \textbf{$\tau$ [s]} & \textbf{$R^2$} \\\midrule
Report Induttore 1 & 110.81 – 111.56 s & 87.3140 & 15.7231 & 0.999505 \\
Report Induttore 2 & 112.02 – 113.95 s & 158.3430 & 13.2844 & 0.997314 \\
Report Induttore 3 & 115.0 – 133.7 s & 185.1847 & 16.2654 & 0.993827 \\
\bottomrule\end{tabular}
\end{document}