Files
engineering-skills/vdi2230/scripts/example_input.json
T

56 lines
944 B
JSON
Raw Normal View History

{
"_comment": "Esempio input VDI 2230 — Giunzione flangia flangia, M12 10.9, DSV, carico alternato",
"_units": "Forze in N, lunghezze in mm, pressioni in N/mm², temperature in K",
"size": "M12",
"strength_class": "10.9",
"thread_type": "coarse",
"joint_type": "DSV",
"lK_mm": 40,
"DA_mm": 36,
"dh_mm": 13.5,
"DA_prime_mm": 60,
"hmin_mm": 20,
"ssym_mm": 0,
"a_mm": 0,
"n_factor": 1.0,
"IBers_mm4": 0,
"FA_max_N": 20000,
"FA_min_N": 5000,
"FQ_max_N": 0,
"MY_max_Nmm": 0,
"mu_G": 0.12,
"mu_K": 0.12,
"mu_T": 0.12,
"qF": 1,
"qM": 1,
"ra_mm": 0,
"pi_max_N_mm2": 0,
"AD_mm2": 0,
"IBT_mm4": 0,
"u_mm": 0,
"MB_max_Nmm": 0,
"alpha_A": 1.7,
"EP_N_mm2": 210000,
"pG_N_mm2": 900,
"fZ_total_um": 12,
"alpha_S": 1.15e-5,
"alpha_P": 1.15e-5,
"dT_S_K": 0,
"dT_P_K": 0,
"meff_actual_mm": 20,
"internal_material": "steel",
"thread_treatment": "SV",
"lGew_mm": 5
}