davideandClaude Sonnet 5 c75dd21551 Exclude temp_* root folders from the CAD index
temp_paris, temp_davide, temp_studi esterni and the other temp_* folders
are personal/scratch work areas on the share: they hold stale or unrelated
copies of codes that also exist in the official project folders, and a real
.asm can numerically coincide with an unrelated file living in one of these
(see docs/formato-asm.md, the 2502020809 false-positive pulling in an
unrelated machine's assembly from temp_studi esterni/Slitter CD549).

Scan now deletes any already-indexed temp_* rows up front and skips walking
those folders going forward, so downstream queries (Form1.cs, ExtractCreoStrings.cs)
never need to filter them out case by case.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-17 16:19:37 +02:00
davideandClaude Sonnet 5 e7b5d85f6b Add family_name and bracket-adjacent placement signals for .asm scanning
Two more real placement forms found by comparing against Creo BOM reports:

- A sub-assembly can be referenced only through a "family_name\0<code>\0"
  metadata field instead of a textual "Componente ID" placement or the
  doubled-NUL pattern (case 9284202452 inside 9284208188_D400.asm, which
  contains 9284202452_C01/_C02/_C03 - previously dropped entirely, along
  with its three children).
- A bare numeric code immediately followed by a family-table bracket
  (<code><GENERIC>, e.g. bearing instances like 2510060303<CUSCI_ACBB7>)
  is a real reference to that instance, even though only the generic file
  is indexed on disk. Previously the instance code silently vanished before
  ever reaching the DB lookup; now it survives placement filtering and ends
  up in the "scartati" (discarded) list instead, so it's traceable rather
  than invisible.

docs/formato-asm.md documents both, bringing the total to four recognized
placement forms.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-17 16:14:52 +02:00
davideandClaude Sonnet 5 a7e0df0247 Fix runaway recursion and two missed-component gaps in .asm scanning
The bare root code of an assembly (e.g. 9284208188, without a _D... suffix)
is always referenced inside its own suffixed sub-assemblies as a genuine
placement pointing back to the general assembly. Following it during
recursive resolution pulled in the entire product tree instead of just the
requested sub-assembly (598 components collected instead of ~65 on
9284208188_D600). Fixed by seeding the visited-codes set with each starting
assembly's root code, in both scripts/ExtractCreoStrings.cs and the two BFS
call sites in Form1.cs (RisolviAlberoComponenti, AssiemeCompleto).

Also closes two recall gaps found by comparing against a real Creo BOM
report: some real placements only show up as the code repeated twice
separated by a NUL byte rather than the usual "Componente ID N (...)" text,
and family-table bearing codes (CUSCI_...) use the same <...> bracket
convention as UNI hardware but weren't recognized.

docs/formato-asm.md documents all three findings.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-17 15:32:55 +02:00
davideandClaude Sonnet 5 9660c4883d Refine .asm component extraction: batch DB queries, wider suffix regex, placement check
- Batch the DB lookup per file instead of per code in scripts/ExtractCreoStrings.cs:
  files_ultima_versione is an unmaterialized view, so each query rescanned the whole
  files table (~230ms) - batching cuts a multi-minute BFS to seconds.
- Widen the code regex to accept a revision letter and a "_..." suffix together
  (e.g. "9284200366A_C01"), and purely numeric "_NNNN" suffixes (e.g. dimensional
  variants like "2702220182_8188"), not just letter+digits.
- Require bare digit-only candidates to also appear inside a real
  "Componente ID N (...)"/"Component id N (...)" placement, filtering out
  incidental references to a containing assembly's own code.
- scripts/ExtractCreoStrings.cs now reports only the direct references of the given
  .asm (one level, matching Creo's own tree for that file) instead of recursing into
  sub-assemblies.
- Port the regex and placement-check refinements to the production
  AssemblyComponentScanner.cs used by the app's "Trova componenti referenziati" and
  "Verifica completezza" phases.
- Document the new false-positive categories (parent/container self-reference,
  suppressed/removed components with residual placement, placement missing
  suffix/bracket detail) in docs/formato-asm.md, generalized beyond the specific
  assemblies used to find them.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-17 14:59:23 +02:00
davideandClaude Sonnet 5 e6de563f60 Distinguish missing STEP from missing CAD source in the final report
A component with no .stp could mean two different things: the CAD source
was never found in the index at all, or it's indexed but nobody exported
the STEP yet. Cross-references the missing codes against cad_index.db
(reusing the phase-2 verification cache when available) and reports each
as EsitoStep.StepMancante vs ComponenteNonTrovato, colored differently.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-17 13:24:25 +02:00
davideandClaude Sonnet 5 1f6cb2da00 Limit step_finali to the BOM's own components
Sub-components discovered recursively in phase 4 exist only to complete
raw/, not to define what final STEP files are expected - including them
made step_finali report unrelated sub-parts as missing/created. Also drops
the now-unused _componentiRisolti field.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-17 12:26:39 +02:00
davideandClaude Sonnet 5 338a7327a0 Resolve UNI family-table hardware (screws/nuts/washers) as components
These appear in the .asm binary as a family-table instance name (e.g.
"R6--_-_U6592<UNI6592>"), not a separate file on disk - only the generic
"uni6592.prt" is actually indexed. Extract just the "<UNI...>" content
instead of the full instance name, in both the standalone script and the
production scanner, so standard hardware stops being silently dropped as
"not found in index".

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-17 12:26:31 +02:00
davideandClaude Sonnet 5 52d126372d Redesign the final STEP phase to build a step_finali folder
Previously it only compared the top-level BOM against step/ and reported
matches, without copying anything. Now it unions the BOM codes with the
sub-components resolved in phase 4, copies every matching .stp into a new
step_finali/ folder, and reports what got created vs what's still missing.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-17 10:23:35 +02:00
davideandClaude Sonnet 5 ee408219bd Show a progress dialog while resolving referenced components
"Trova componenti referenziati" ran the recursive BFS synchronously on the
UI thread with no feedback. Runs it on a background task instead and shows
a modal dialog with a percentage bar, updated as each .asm in the queue is
processed.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-17 09:55:14 +02:00
davideandClaude Sonnet 5 bb99c4f4c5 Apply the ModelView# false-positive fix to the production scanner
The standalone script already excluded internal saved-view IDs
(ModelView#<numero>) from the referenced-codes heuristic; the app's own
"Trova componenti referenziati" phase used the same regex without the fix.
Ports the lookbehind so both stay consistent, per docs/formato-asm.md.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-17 09:55:06 +02:00
davideandClaude Sonnet 5 4a3f0a4cf8 Cache DB verification result and reuse it when creating the raw folder
Avoids re-running the same lookup against cad_index.db twice when the
user already clicked "Verifica presenza nel DB" before "Crea cartella raw".

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-17 09:13:38 +02:00
davideandClaude Sonnet 5 b77ec39c5b Add DB presence check button to import phase
Lets the user spot missing components right after import instead of
discovering it later in the raw-folder step, by coloring each grid row
green/red based on a lookup against cad_index.db.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-17 09:08:33 +02:00
davideandClaude Sonnet 5 f28cb818bd Add standalone .asm BOM-extraction scripts and format documentation
Reverse-engineered the Creo .asm binary format enough to extract referenced
component codes via a text heuristic, mirroring AssemblyComponentScanner's
approach and Form1's recursive resolution against cad_index.db. Documents
known false-positive classes (ModelView# view IDs, self-references, and
phantom references to superseded/renamed codes).

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-17 09:01:45 +02:00
davideandClaude Sonnet 5 52483177f0 Add wizard UI, general-assembly resolution, and test suite
Restructure Form1 into a sequential wizard (database -> import -> raw ->
recursive component resolution -> completeness/STEP report), fix
case-sensitivity bugs in codice/tipo_file lookups and a word-boundary gap
in the assembly scanner that missed _D100-style sub-assembly references,
and treat the distinta's general assembly as an ordinary CSV row (derived
from the DBP_<codice>_<timestamp> filename) instead of special-casing it
throughout. Also adds CadSearchGui.Tests (xUnit) covering the scanner,
filename parsing, and the case-insensitive DB lookup behavior.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-16 16:25:52 +02:00
davideandClaude Sonnet 5 146ce78eae Index Unificati/Commerciali, merge cleanup buttons, report unmatched components
- Add 'Unificati' and 'Commerciali' as indexed root folders alongside the
  existing four, updating Indexer.CartelleRadice and the docs.
- Replace the separate "Pulisci cartella raw" / "Pulisci cartella step"
  buttons with a single "Pulisci raw e step" that clears both under one
  confirmation; falls back to a folder picker when no path is known yet
  in the session instead of staying disabled.
- "Trova componenti referenziati" now also writes a persistent summary
  (PRT/sub-assemblies found and copied, codes not found) to the main
  window's status line, not just the popup dialog, and reports clearly
  when no database is loaded instead of failing silently.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-16 12:05:07 +02:00
davideandClaude Sonnet 5 e56a3be5b4 Add recursive component resolution for assembly dependencies
Assemblies reference other assemblies and parts internally; a flat
single-level copy into raw/ left Creo unable to load models ("Dati di
input non completi"). AssemblyComponentScanner heuristically extracts
component codes embedded as readable strings inside the otherwise
binary .asm files; each candidate is validated against the index (which
filters out scan noise), copied into raw/, and if it's itself an
assembly, queued for the same treatment until the whole tree resolves
to PRT leaves. PrtMancantiForm reports what was found and copied.

Also ignore Creo Distributed Batch job files (*.dxc).

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-16 11:40:34 +02:00
davideandClaude Sonnet 5 97d53a16dd Add raw-folder step, redesign UI, remember last DB path, add README
- Split the import flow into explicit steps: import/preview CSV, then a
  separate "Crea cartella raw" button that looks up CAD paths and copies
  matched files into raw/ next to the source distinta file.
- Redesign the top panel with grouped, auto-sized sections (database vs.
  import) instead of hand-tuned row heights, fixing overlap/clipping bugs;
  style the primary action button and polish the results grid.
- Remember the last successfully loaded database path in
  %AppData%\CadSearchGui\ultimo_db.txt so it reloads automatically on
  future launches regardless of the working directory.
- Ignore the /step/ working folder.
- Add a README with build/run/publish instructions and project overview.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-16 10:59:16 +02:00
davideandClaude Sonnet 5 98c513dd64 Replace CAD search tab with CAD-path lookup for imported components
Drop the free-text search UI; the single remaining view imports the
Distinta Base, generates the CSV, and looks up each Componente code in
the indexed DB (files_ultima_versione, prt/asm) to show its CAD file
path directly in the results grid.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-16 10:28:15 +02:00
davideandClaude Sonnet 5 f88639bf4b Add Distinta Base import tab: parse .xls/.xml export to CSV with preview
Reads the ERP-exported "Distinta Base" file (SpreadsheetML XML or real
binary .xls/.xlsx via ExcelDataReader), extracts Componente/Descrizione,
writes a CSV and previews it in a new tab alongside the existing CAD
search. Also ignore the exported Excel/CSV files dropped in the repo root.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-16 10:22:16 +02:00
davideandClaude Sonnet 5 82a69e0d20 Add CadSearchGui: WinForms app to index and search the CAD archive
Indicizza le cartelle __Accessori, __B.end, __Corpi, __Fondi in un DB
SQLite locale ed espone una GUI di ricerca (codice, tipo, cartella,
solo ultima versione) con aggiornamento incrementale dell'indice e
stima del tempo rimanente.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-09-16 09:58:55 +02:00